Fuel Tank Monitoring Solutions


P-SENTS™ - Remote Fuel Tank Monitoring Solution


An easily installed system to monitor petrol station tank levels via the internet.

Logistic departments of petrol stations benefit from:

- Improved delivery schedules

- Efficient route planning

- Optimised inventory management

- Lower capital requirements

How it works?

1. Level sensors and telemetry unit are installed at the petrol station.

2. Petrol levels are sent via SMS to a central database which process automatically the data from each tank.

3. Users can any time request an update of the tank level and access the data via the internet.
Download Product Brochure

 

WS-900HZ2 Industrial Wireless Sensor


*License-free Spread Spectrum Technology

*900MHz or 2.4GHz Frequency Range

*1000 mW RF Output Power

*Multiples of 1x 4-20mA Analog Input, 2x Discrete Inputs

*Multiples of 1x 4-20mA output, 2-discrete outputs

*Other input Options such as 0 - 5Volt and others available

*Designed for Rugged Industrial Environment

*Up to 10 miles of Communications Distance

*Enclosures rated for Hazardous Environment

*Option of Point Level Sensors, Continous Level Sensor or Multi-point flaot sensor for varios depths and materials

 

PT500 Submersible Liquid Level Transmitters


Simple to install liquid level measurement

High precision, solid state signal: 4-20 mA

Exclusive, removable and reusable cage saves you money when replacing the sensor (patent pending)

Optional 1-1/2" tri-clover with 3/4" diaphragm or 1-1/2" diaphragm process connection with removable cage

1/2" NPTM on cable end for use with conduit

cCSAus hazardous location approved

- Class I, Div. 1, Groups C & D

- Class I, Zone 0, Group IIB

 

PT400 Amplified Output Pressure Transducers


Cost effective

Durable all welded construction

Available ranges from 0 up to 20,000 psi

Standard outputs: 4-20 mA, 0-5 VDC, 0-10 VDC

High vibration

High overpressure capability

Zero and span adjustments

1/4-18 NPTM fitting standard

+/- 0.25% BFSL accuracy; +/-0.5% BFSL accuracy on ranges greater than 5,000 psi (voltage output only)

cCSAus hazardous location approved

- 0-5 VDC, 0-10 VDC Class I, Div. 2, Groups C & D Class I, Zone 2, Group IIB

- 4/20 mA Class I, Div. 1, Groups C & D Class I, Zone 0, Group IIB

 

RPM Series Resistive Chain Level Measurement


Continuous level indication

Resistive chain or loop powered 4-20 mA output

Rugged and highly reliable

Anti-stick float design

0.5 in./0.25 in. resolution

Several hazardous location approvals



The RPM series custom continuous level sensors are designed to meet demanding customer requirements for reliable operation. Models are available in lengths up to 6 m (20 ft.) with a variety of mounting configurations. Output options include resistive chain or loop powered 4-20 mA

 

LPU2127 Loop Powered Ultrasonic Level Sensor


1 to 25 ft. (0.3 to 7.6 m) detection range on liquids

1 to 10 ft. (0.3 to 3 m) detection range on solids

Low-power continuous level measurement

Works on solids or liquids

Integrated keypad and LCD display

Loop-powered 4-20 mA output

Easy to install

Internal temperature compensation

Rugged PDVF (Kynar®) transducer housing

PET sensor housing

Maintenance free

 

LPU2428 Loop Powered Ultrasonic Level Sensor


1 to 25 ft. (0.3 to 7.6 m) detection range on liquids

1 to 10 ft. (0.3 to 3.0 m) detection range on solids

Low-power continuous level measurement

Works on solids or liquids

Loop-powered 4-20 mA output

Easy to install

Internal temperature compensation

Rugged PVDF (Kynar) transducer housing

PC/PBT sensor housing

Maintenance free

Set up internal parameters using RST-4001

Volume, flow and totalization measurements