Fuel Tank Monitoring Solutions


P-SENTS™ - Remote Fuel Tank Monitoring Solution


An easily installed system to monitor petrol station tank levels via the internet.
Logistic departments of petrol stations benefit from:
- Improved delivery schedules
- Efficient route planning
- Optimised inventory management
- Lower capital requirements
How it works?
1. Level sensors and telemetry unit are installed at the petrol station.
2. Petrol levels are sent via SMS to a central database which process automatically the data from each tank.
3. Users can any time request an update of the tank level and access the data via the internet.

 

WS-900HZ2 Industrial Wireless Sensor


*License-free Spread Spectrum Technology

*900MHz or 2.4GHz Frequency Range

*1000 mW RF Output Power

*Multiples of 1x 4-20mA Analog Input, 2x Discrete Inputs

*Multiples of 1x 4-20mA output, 2-discrete outputs

*Other input Options such as 0 - 5Volt and others available

*Designed for Rugged Industrial Environment

*Up to 10 miles of Communications Distance

*Enclosures rated for Hazardous Environment

*Option of Point Level Sensors, Continous Level Sensor or Multi-point flaot sensor for varios depths and materials

 

PT500 Submersible Liquid Level Transmitters


Simple to install liquid level measurement

High precision, solid state signal: 4-20 mA

Exclusive, removable and reusable cage saves you money when replacing the sensor (patent pending)

Optional 1-1/2" tri-clover with 3/4" diaphragm or 1-1/2" diaphragm process connection with removable cage

1/2" NPTM on cable end for use with conduit

cCSAus hazardous location approved

- Class I, Div. 1, Groups C & D

- Class I, Zone 0, Group IIB

 

PT400 Amplified Output Pressure Transducers


Cost effective

Durable all welded construction

Available ranges from 0 up to 20,000 psi

Standard outputs: 4-20 mA, 0-5 VDC, 0-10 VDC

High vibration

High overpressure capability

Zero and span adjustments

1/4-18 NPTM fitting standard

+/- 0.25% BFSL accuracy; +/-0.5% BFSL accuracy on ranges greater than 5,000 psi (voltage output only)

cCSAus hazardous location approved

- 0-5 VDC, 0-10 VDC Class I, Div. 2, Groups C & D Class I, Zone 2, Group IIB

- 4/20 mA Class I, Div. 1, Groups C & D Class I, Zone 0, Group IIB

 

RPM Series Resistive Chain Level Measurement


Continuous level indication

Resistive chain or loop powered 4-20 mA output

Rugged and highly reliable

Anti-stick float design

0.5 in./0.25 in. resolution

Several hazardous location approvals



The RPM series custom continuous level sensors are designed to meet demanding customer requirements for reliable operation. Models are available in lengths up to 6 m (20 ft.) with a variety of mounting configurations. Output options include resistive chain or loop powered 4-20 mA

 

LPU2127 Loop Powered Ultrasonic Level Sensor


1 to 25 ft. (0.3 to 7.6 m) detection range on liquids

1 to 10 ft. (0.3 to 3 m) detection range on solids

Low-power continuous level measurement

Works on solids or liquids

Integrated keypad and LCD display

Loop-powered 4-20 mA output

Easy to install

Internal temperature compensation

Rugged PDVF (Kynar®) transducer housing

PET sensor housing

Maintenance free

 

LPU2428 Loop Powered Ultrasonic Level Sensor


1 to 25 ft. (0.3 to 7.6 m) detection range on liquids

1 to 10 ft. (0.3 to 3.0 m) detection range on solids

Low-power continuous level measurement

Works on solids or liquids

Loop-powered 4-20 mA output

Easy to install

Internal temperature compensation

Rugged PVDF (Kynar) transducer housing

PC/PBT sensor housing

Maintenance free

Set up internal parameters using RST-4001

Volume, flow and totalization measurements